Add to Cart
Why do we need compressed Air Filters in our production?
Compressed air is full of particles, aerosols oil and oil vapors (in oil injected pistons and screws) that contaminate the compressed air and can lead potential harm to its end users (equipment that uses that compressed air). Incorporating the correct inline filter can help you eliminate the unwanted particulates as well as aerosols and vapors. The amount of compressed air filters and types needed will be dependent on the quality of air your application and or your process requires. Let’s take a look at the different types of air filters and the questions that will help you choose the correct filter.
①Assess the requirements of your application. Different industry require different solution. | ③Any specific micron of filtration performance you required? | |||||||
②What type of filtration is needed? Coalecent filter material removes solid and liquied contaminants from gas streams. Particulate filter media removes solid from gas streams. Absorber media removes hydrocarbon vapors from gas streams. | ||||||||
④What are the working conditions of your application? Mainly criteria of consider : Flow, working pressure, temperature,pressure loss,material of structure (stainless steel, aluminum alloy, mild steel, carbon steel) | ||||||||
⑤Filter flow rate from how much SCFM? Pressure drop should be less than **bar? For saving the cost and protect environment. | ||||||||
PRODUCT OVERVIEW
Commodity | Compressed Air Filter | |||||
Model | YD017 | |||||
Flow rate | m³/min~ m³/min | |||||
Element grade | 5μm/1μm /0.01μm/0.001mg/m³ | |||||
Working pressure | 143 psi g | |||||
Working temperature | 1.5℃~80℃ | |||||
Material | Aluminum Alloy | |||||
Color of housing | Red | |||||
Trade term | EXW & FOB SHENZHEN | |||||
Package | Internal Box & External Carton | |||||
Warranty | 15 years for filter housing, 4000-6000 hours under rated working conditions for Filter Element | |||||
Filter Element Grade
Filtration Grade | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
PF | AO | AA | AX | ACS | AR | AAR | |
Particle removal (ISO12500-3) | 5μm | 1μm | 0.01μm | 0.01μm | - | 1μm | 0.01μm |
Outlet oil aerosol concentration (ISO12500-1) | 5mg/m³ | 0.6mg/m³ | <0.01mg/m³ | <0.001mg/m³ | <0.004mg/m³ | - | - |
Filtration performance of Particle (ISO12500-3) | - | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% | 99.999+% |
Filtration performance of (ISO12500-1) | 50% | 80+% | 99.9+% | 99.99+% | - | - | - |
Element spanlife | 6000 hours | 6000 hours | 6000 hours | 6000 hours | 2000-3000 hours | 4000-6000 hours | 4000-6000 hours |
Precede with | Before Refrigerated Air Dryer | after air dryer | after AO | after AA | before AX | after desiccant dryer | after AR |
Model | Pipe size | Flow rates | Dimension (mm) | |||||||
L/S | m³/min | scfm | W(Width) | D (Depth) | H (Height) | A | B | C(clearance for housing) | ||
YD017 | RC1/2" | 16.7 | 1.0 | 35.3 | 89 | 79 | 246 | 40 | 186 | 118 |
YD025 | RC3/4" | 25.0 | 1.5 | 53.0 | 89 | 79 | 246 | 40 | 186 | 118 |
YD030 | RC1/2" | 30.0 | 1.8 | 63.6 | 89 | 79 | 280 | 40 | 220 | 158 |
YD035 | RC3/4" | 33.3 | 2.0 | 70.6 | 89 | 79 | 280 | 40 | 220 | 158 |
YD058 | RC3/4" | 46.7 | 2.8 | 98.9 | 120 | 110 | 377 | 55 | 276 | 195 |
YD068 | RC1" | 60.0 | 3.6 | 127.1 | 120 | 110 | 377 | 55 | 276 | 195 |
YD080 | RC1" | 80.0 | 4.8 | 169.5 | 120 | 110 | 477 | 55 | 377 | 290 |
YD145 | RC1-1/2" | 120.0 | 7.2 | 254.2 | 120 | 110 | 477 | 55 | 377 | 290 |
YD220 | RC2" | 200.0 | 12.0 | 423.7 | 162 | 151 | 676 | 64 | 566 | 480 |
YD260 | RC2-1/2" | 233.3 | 14.0 | 494.4 | 162 | 151 | 676 | 64 | 566 | 480 |
YD330 | RC2" | 267.2 | 16.0 | 564.8 | 162 | 151 | 984 | 64 | 875 | 780 |
YD360 | RC2-1/2" | 317.3 | 19.0 | 670.7 | 162 | 151 | 984 | 64 | 875 | 780 |
YD405 | RC2-1/2" | 367.4 | 22.0 | 776.6 | 200 | 189 | 757 | 78 | 634 | 560 |
YD430 | RC3" | 467.6 | 28.0 | 988.4 | 200 | 189 | 757 | 78 | 634 | 560 |
YD620 | RC3" | 620.0 | 37.2 | 1313.6 | 200 | 189 | 1012 | 78 | 889 | 780 |
Technical requirements | Maximum operating pressure: 10 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C |
Pressure | Barg | 1 | 2 | 3 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 |
Psig | 15 | 29 | 44 | 73 | 87 | 100 | 116 | 131 | 145 | 160 | 174 | 189 | 203 | 219 | 232 | |
Correction factor | 0.38 | 0.53 | 0.65 | 0.85 | 0.93 | 1.00 | 1.07 | 1.13 | 1.19 | 1.23 | 1.31 | 1.36 | 1.41 | 1.46 | 1.51 |
YD017-YD035
YD058-YD145
YD220-YD620