Ask Latest Price
Video Channel
Model No. :YF-B040
Origin :China
Element Serve Life :6000~8000 Hours
Trademark :Yuka
HS Code :8421399090
Clapboard :Without Clapboard
Filter Number :1
Medium Material :Fiberglass
Type :Cartridge Filter
Material :Aluminum Alloy
Housing Serve Lige :15 Years
Filtration Performance :From 5 μm To 0.01μm
Operate Temperature :1.5~80ºc
Resistance Corrosion :Inside And Outside
Transport Package :Brown Inner Box & Cardboard
Efficiency :F5
Filtration Grade :Medium Filter
Maxi. Operate Pressure :1.6 Mpa
Belong To :Air Compressor System
Color :Light Blue
Connection :Rc1"
Flow Rate :2.0 M³/Min
Filter Type :Coalescing
Option Parts :Connection Kit
Configuration :Manual Ball Valve
Element Top Cap :Diversion Fin
Specification: Dimension :96 X 79x 274mm
Place of Origin :China
Brand Name :Yuka
Price :Negotiable
Packaging Details :Box Package
Delivery Time :3-7working days
Payment Terms :L/C,T/T
MOQ :50pcs
Supply Ability :300,000pcs/month
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description
Product Description



How Does a Compressed Air Filter Work?


Air compressor filter does is keep water, oil and dirt from down to your pneumatic tools, making them essential to the overall health of your air system. These kinds of dust or particles can damage or destroy your equipment if you don’t offer proper filtration. If they pass through those tools, your project will be affect in negatively, such as by destroying a paint job or contaminating foods in production facilities.

One of the benefits of Air Filters is that they are reasonable investments. What you have to keep up with wear and replace them in time, it costs far less to purchase new filters than to pay for repair costs for damaged pneumatic equipment or air compressors. You’ll receive result in positive, as keeping the air that passes through your compressor clean is critical to tool and equipment health as well as work quality.


YUKA YF-B Series Feature & Benefit

>HV fiber glass Element Material, ensure filtration performance up to ISO8573.1-2010 Standard

>Aluminium alloy die-casting filter housing, spanlife with 15 years

>Stainless Steel Filter element supports mesh to prevent the secondary pollution from flowing to the back end of the compressed air

>7 filtration grades to removel for different contaminate well

>Flow rate from 1.0 to 48m³/min,

>Maximum operating pressure: 16 bar(g)

>Maximum operating temperature: 80 °C



7 Grades Filter Element: PF/AO/AA/AX/ACS/AR/AAR
PF AO AA AX ACS AR AAR
As a primary filter, particles whose diameter more than 5μm can be remove,the maxi. residual oil content is negligible High efficiency general protection, dust particles, water mist & oil mist whose diameter more than 1μm can be removed, the residual content of oil mist does not exceed 0.6mg/m³ (21ºC),1ppm(w). High effiency oil remove filtration, dust particles, water mist and oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.01mg/m³(21ºC),0.01ppm(w) Ultra-efficient filtration, dust particles, water mist&oil mist whose diameter more than 0.01μm can be removed, the residual content of oil mist does not exceed 0.001mg/m³(21ºC),0.001ppm(w) Dust particles whose diameter more than 0.01μm, oil vapor &odor can be removed, the maxi. resident content of oil vapor does not exceed 0.003mg/m³(21ºC),0.003ppm(w) Dust particles whose diameter more than 1μm can be removed Dust particles whose diameter more than 0.01μm can be removed



International test and measurement standard ISO12500
>ISO 12500 has made clear a general test and definition method for the compressed air filter manufacturers. The main performance
parameters are the air inlet oil content and particles size distribution of the solid particles.
>ISO12500-1 specifies the test requirements for the filtration performance of oil aerosol in the coalescing filter.
>ISO12500-2 specifies the test requirements of adsorption filters for the removal performance of steam adsorption.
>ISO12500-3 specifies the requirements for removal of particulate matter from solid pullutants.



Product are test with the international advanced testing equipment based on standard ISO12500, Which is equivalent to the standard ISO8573.1-2010 quality standard, and provide filter performance test report.
Filtration Grade PF AO AA AX ACS AR AAR
Size of solid particles(ISO12500-3) 5μm 1μm 0.01μm 0.01μm - 1μm 0.01μm
Filtration performance of solid particles(ISO12500-3) - 99.999+% 99.999+% 99.999+% 99.999+% 99.999+% 99.999+%
Filtration performance of oil(ISO12500-1) 50% 80+% 99.9+% 99.99+% - - -
Residual oil content(ISO12500-1) 5mg/m³ 0.6mg/m³ <0.01mg/m³ <0.001mg/m³ <0.004mg/m³ - -

Product Picture
Air Compressor Filter for Nitrogen Generator



Filter Element
Air Compressor Filter for Nitrogen Generator

Technical Specification
The flow rate below is the treatment capacity of compressed air under rated working pressure 7 barg (100psi g).
For application in other working pressure, please refer to the correction factors.
Model Pipe size Flow rates Dimension (mm)
L/S m3/min scfm W(Width) D(Depth) H(Height) A B C(clearance for housing)
YF-B010 RC1/2" 16.7 1.0 35.5 96 79 245 29 180 118
YF-B020 RC3/4" 25.0 1.5 53.0 96 79 245 29 180 118
YF-B030 RC3/4" 30.0 1.8 63.6 96 79 274 29 209 153
YF-B040 RC1" 33.3 2.0 71.0 96 79 274 29 209 153
YF-B060 RC1" 60.0 3.6 127.0 138 111 349 37 276 208
YF-B070 RC1" 83.3 5.0 177.0 138 111 450 37 377 303
YF-B080 RC1-1/2" 125.0 7.5 265.0 138 111 450 37 377 303
YF-B090 RC2" 166.7 10.0 353.1 174 142 558 58 500 467
YF-B100 RC2-1/2" 216.7 13.0 459.0 174 142 558 58 500 467
YF-B110 RC2" 283.3 17.0 600.0 174 142 838 58 780 794
YF-B120 RC2-1/2" 316.7 19.0 671.0 174 142 838 58 780 794
YF-B130 RC3" 416.7 25.0 883.0 220 184 616 74 542 514
YF-B140 RC4" 466.7 28.0 989.0 220 184 616 74 542 514
YF-B150 RC3" 683.3 41.0 1448.0 220 184 892 74 798 764
YF-B160 RC4" 800.0 48.0 1695.0 220 184 892 74 798 764
Technical requirements Maximum operating pressure: 16 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C
Pressure Barg 1 2 3 4 5